Leading 1 of Installation and User Guide. Compatible Equipment. Remote Keypad. Internal Sounder. Authenticated: The product is verified as being authentic; however, this does not guarantee the condition or fit for purpose of the product. Scantronic - Wired 7 zone intruder alarm panel. Contact us about this product. Easy to operate Each system has full and part set facilities, the ability to change access codes and remote keypads to give a high level of security and total peace of mind.
View Speech Diallers. Choice of keypads Choose between including a built-in keypad EUR or an external keypad the EUR - see image dependent on the site or building. Providing greater flexibility on your installations. Key-in your four digit user code. The exit tone will start. Leave premises via the designated exit door. Tone will stop after preset time. The alarm system will then be SET. Your alarm system may have been installed to allow you to to have part of the premises set while other area s are.
This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Every effort has been made to ensure that the contents of this book are correct, errors and omissions excepted.
However, neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or To switch the bells off: Key-in your user code.
The sounders will stop and the zone light s for the detectors that triggered the alarm will glow. Reset system: You must reset the system before it can be used again.
Key-in your access code again. All the zone lights should go off. The system is now ready for Mar 20, This rest of this guide shows the simple procedures required to operate and administer the system. Possibly switching off mains supply and turning on again has spiked it.
With this particular panel, if just the power led is illuminated then does this indicate that panel is already restored to factory defaults and is awaiting programming? Before removing control panel battery the external strobe was flashing every few seconds or so, which I assume is because the external alarm had been triggered when mains power was removed and had timed out after the set 20 minute period, leaving just the strobe flashing.
I understand that these panels are not very expensive should the need arise to replace it? I will check it over thoroughly first though and will also check the two fuses on the pcb. If these are ok is there anything else I should check? Also, if I am in engineer's mode, does this mean that I can disconnect and replace the external bell box battery without setting the alarm off? Whilst in engineer mode all tampers and faults are "ignored" and therefore won't trip the alarm.
On the the Green AC led just denotes whether mains power is present. The only way to tell if system is defaulted is if the eng code is default and used to be something else then yes it's defaulted. There are many things that could be wrong, but testing voltages etc is a good start.
I'm sure I read you have the manual, read it front to back to ensure you understand the system. TheAlarmMan , 12 Oct Hi Everyone! I'm just letting you know that I replaced the battery, reset the panel to factory defaults, and reprogrammed system and it is now working fine again.